This blood pressure monitor has achieved the highest possible grade (A/A) according to the criteria of the British Hypertension Society. This monitor further complies with the standard required by the Association for the Advancement of Medical Instrumentation (AAMI).
This blood pressure monitor has passed the European Society of Hypertension criteria by achieving all requirements. This monitor further complies with the standard required by the Association for the Advancement of Medical Instrumentation (AAMI).
HEMODYNAMIC STABILITY DETERMINATION (HSD) - eliminates all possible blood pressure measurement error caused by mental and physical stress and avoids unnecessary multiple measurements to attain an average of your blood pressure. The lack of rest condition, which is detected by the HSD technique, is the most common error in the blood pressure diagnosis. The blood pressure results have to be obtained in sufficient rest condition in order to have an accurate medical judgement of a patient‘s blood pressure status.
Tracking variations in blood pressure readings between morning and evening is important for physicians to better understand, diagnose and manage hypertensive patients or patients with other forms ofheart diseases. Blood pressure changes throughout the day and is influenced by physical and mental factors, measurement conditions and time.
Based on personal demand the talking function can be switched on or off. The unit offers a full talking guideance from start until the blood pressure is displayed.
The National High Blood Pressure Education Program Coordinating Committee (JNC-7) has developed a blood pressure standard, classifying blood pressure ranges into 4 stages. This unit is equipped with innovative blood pressure risk indicator, which visually indicates the assumed risk level (prehypertension / stage 1 hypertension / stage 2 hypertension) of the result after each measurement.
The units equipped with Irregular Heartbeat (IHB) Detector allow those who have an irregular heartbeat to obtain accurate measurements alerting the user of the presence of an irregular heartbeat during the measurement. The Irregular heartbeat algorithm automatically determines if the measurement is usable or needs to be repeated. If the irregular heartbeat symbol is shown frequently the doctor needs to be consulted.
Most regulatory agencies suggest recalibration of a unit’s pressure readings, by due to the technical constraints; the unit can only be recalibrated by manufacturer or via sophisticated equipment. Knowing the importance of recalibration to the units and the users, Rossmax devoted 2 years to develop the world’s first mobile calibration system. Simply connect Rossmax unit to the system, with its intuitive operation, now the recalibration is only a matter of seconds.
DK Technology is a combination of the traditional Oscillometric method and Korotkoff sound method. With a microphone built into the arm cuff, DK Technology actually listens like your doctor when taking a reading. Exclusive DK Technology delivers ultimate accuracy by using both pressure and sound. The monitor is supported with an advanced „dual-sensor“ cuff system. It has been shown that a device using the auscultatoric method has the potential to match the gold standard method more closely than devices using oscillometric methods.
Real Fuzzy Technology determines ideal cuff pressure based on one‘s systolic blood pressure and arm size. Users no longer need to pre-set the inflation level before measurement. The technology eliminates arm discomfort through unnecessary high inflation settings and also prevents inaccurate readings caused by erroneous cuff inflation levels.
Smart Sense Technology utilizes an advanced air control system. The electronic deflation valve delicately controls the deflation rate. It allows the monitor to detect and analyze pulse signals as well as adjusting cuff pressure during deflation. This significantly aids in making more precise analysis, improving accuracy silently and efficiently.
This unit uses the oscillometric method to detect your blood pressure. Manual inflation to the appropriate pressure, during the deflation, the device will detect the amplitude and slope of the pressure oscillations and thereby determine for you the systolic pressure, diastolic pressure, and pulse.
Convenient, Durable and Accurate! The digital operation and display design of Rossmax Digital Gauge clearly indicates the pressure, heartbeat and deflation rate on the same LCD display. A virtually indestructible design can withstand repeated drops of 5 feet or more. Splash resistant housing makes it possible to operate in harsh environments. The Digital Gauge is equipped with a 10,000-cycles calibration reminder, which greatly contributes to the accuracy and durability of the unit. The backlight screen design is convenient for users that need lighting.
Body movement indication - The “Movement Detector” helps reminding the user to remain still and is indicating any body movement during measurement. The specified icon appears once a “body movement” has been detected during and after each measurement. Such detector helps remind the users to remain still during the measurement process and increases the accuracy of the measurement.
In the auscultatory mode the cuff will be automatically inflated. During deflation the Korotkoff sound will be detected manually with the stethoscope and the marker. Systolic and Diastolic values will be displayed on the device which can be used for fully automatic measurements as well.
Inhalation
Utilizing the new technologies to improve the management and treatment of asthma, COPD and other respiratory conditions. With nebulizer systems, patients have the ability to effectively manage and treat their respiratory condition anywhere, anytime.
Possibly the lowest dB value among the compressor nebulizers. All the noise and vibrations are significantly reduced via the unique silencer and vibration-absorber design The compact design with optimal heat dissipation system allows durable, powerful operation.
VAT - Valve control nebulization rate - With the adjustable bottle for flow rate control, the delivery of any mediation will be fast and efficient. The Valve Adjustable Technology (VAT) is based on different levels of flow rate (0.2 – 0.4 CC/min). The flow rates can be adjusted by the user in a very easy way without exchanging parts. High flow rate is for high viscosity medications and high breathing capacity user whereas the low flow rate is recommended for children or infant. Thanks to the reduction of wasted medication, VAT is also recommended for severe respiratory disorders such as COPD and Asthma as well as intensive use in general.
Fever
The patented “PLUG & SECURE” probe cover can offer an easy and accurate ear temperature measurement. Users can easily assure the probe cover is attached and the appliance is ready to use. The well-designed heat insulation probe can ensure accurate, consistent reading and short interval between each measurement. Clinical validation complies with ASTM 1965-98 and PrEN 12470-3.
The continuous ear scanning mode views the entire ear canal and looks for the highest temperature that can be detected. Simply press and hold the start button for 3 seconds, gently rotate the probe inside the ear canal in a circular manner and the most accurate reading will appear.
For Non-Contact temperature measurement - The advanced infrared temperature measuring technology provides safe, accurate,reliable and hygienic readings for measuring both forehead and ambient temperature. The forehead temperature reading lookup table was calculated and developed based on systematic skin clinical data statistics to accommodate fever and non-fever subjects, under different operating environment. The one second measurement thermometer without contacting skin is a suitable choice for obtaining body temperature and prevents cross contamination by measuring around 5 cm from the forehead.
World’s smallest ear probe 5.9mm provides best comfort for infants and adults during measurement and comes with most accurate and stable result.
1~60 seconds quick measurement with flashing number display and Bi-Bi sound to remind you when measurement completes.
Water-proof probe, easy to clean the device and probe by using cotton swab with the Alcohol.
Hot - Cold - Pain
Profound knowledge on carbon materials has led to the development of a carbon fiber fabric with the ability to emit FIR (far infrared) energy. Rossmax’ state of the art production facilities in combination with highest quality standards make this fabric a unique base material for a variety of different applications, including medical therapy. Compared to conventional heating pads which only produce “surface heat”, the Rossmax Infrared heating wraps are using the superior far infrared technology (FIR). Infrared is a scientifically proven form of heat therapy that works more efficiently and effectively than traditional heating techniques. Most notably, far infrared is a completely safe form of thermal radiation, as it does not emit the harmful Electromagnetic Frequencies (EMF) like most other electronic products. Unlike conventional heating technology which is using metal wires as heating elements, this unique technology uses a carbon fiber fabric which in itself is electrically conductive and therefore does not use any wires. The fabric naturally emits infrared energy which supports various therapeutic applications. No matter if you are suffering from acute or chronic pain or just use it for preventive treatment; Rossmax ProWraps are the right choice.